Custom Rectangular tube adapter STL file 100x100 mm to 35x35 mm – transition: 30 mm 📦#4994
Generation date: 2025-12-19
3D model download
Free- rectangular-to-rectangular-duc_model4994-nb0_dd{id}.stl : 1.5 Mo
STL
Mesh quality :
0.0005
0.05
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Values for this model
This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
| Parameter | Value | |
|---|---|---|
| #1 | side A internal width | 100 mm (≃3 15/16 in) |
| #2 | side A internal height | 100 mm (≃3 15/16 in) |
| #3 | sleeve length on side A | 30 mm (≃1 3/16 in) |
| #4 | side B internal width | 35 mm (≃1 3/8 in) |
| #5 | side B internal height | 35 mm (≃1 3/8 in) |
| #6 | sleeve length on side B | 50 mm (≃1.97 in) |
| #7 | thickness | 2 mm (≃0.08 in) |
| #8 | transition length | 30 mm (≃1 3/16 in) |
| #9 | Y offset | 0 mm (0 in) |
| #10 | Z offset | 0 mm (0 in) |
| #11 | end chamfers | inside |
| Metadata | Value |
|---|---|
| external width on side A | 104 mm (≃4.09 in) |
| external height on side A | 104 mm (≃4.09 in) |
| external width on side B | 39 mm (≃1.54 in) |
| external height on side B | 39 mm (≃1.54 in) |
| total length | 110 mm (≃4.33 in) |
Parameter overview
Labels are used in the naming of the downloaded 3D files.
| Parameter | Label |
|---|---|
| #1 side A internal width | widRA |
| #2 side A internal height | heiRA |
| #3 sleeve length on side A | lenSA |
| #4 side B internal width | widRB |
| #5 side B internal height | heiRB |
| #6 sleeve length on side B | lenSB |
| #7 thickness | thi |
| #8 transition length | tra |
| #9 Y offset | ofsY |
| #10 Z offset | ofsZ |
| #11 end chamfers | cha |
Related 3D models
To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter
Rectangular pipe adapter STL 3D file 77x34 mm to 77x34 mm – transition: 30 mm (📦 #4959)
1 object(s) - format STL
Rectangular duct adapter exported as STL 3D file. On both side A and side B, the internal cross-section is 77x34 mm, with a rectangular geometry. Both side A and side B sleeves share the same insertion length of 30 mm. Between the two sleeves, the transition section adds 30 mm, giving an overall length of 90 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 77 | mm |
| side A internal height | 34 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 77 | mm |
| side B internal height | 34 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 30 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL 3D file 77x34 mm to 34x77 mm – transition: 30 mm (📦 #4958)
1 object(s) - format STL
Rectangular adapter downloadable as STL 3D file. The internal cross-section on side A is 77x34 mm (rectangular), while side B is 34x77 mm (rectangular). Each sleeve provides an insertion length of 30 mm. Between the two sleeves, the transition section adds 30 mm, giving an overall length of 90 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 77 | mm |
| side A internal height | 34 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 34 | mm |
| side B internal height | 77 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 30 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL file 122.3x60.3 mm to 116x56 mm – transition: 20 mm (📦 #7196)
1 object(s) - format STL
3D STL file for rectangular duct connector. Side A uses an internal cross-section of 122.3x60.3 mm (rectangular), whereas side B is 116x56 mm (rectangular). The sleeve on side A provides an insertion length of 25 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 75 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 122.3 | mm |
| side A internal height | 60.3 | mm |
| sleeve length on side A | 25 | mm |
| side B internal width | 116 | mm |
| side B internal height | 56 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular tube adapter STL 3D file 122.3x60.3 mm to 116.3x56.3 mm – transition: 20 mm (📦 #7193)
1 object(s) - format STL
Rectangular duct fitting provided as 3D STL file. The internal cross-section on side A is 122.3x60.3 mm (rectangular), while side B is 116.3x56.3 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 30 mm. The transition section runs for 20 mm and the overall length is 75 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 122.3 | mm |
| side A internal height | 60.3 | mm |
| sleeve length on side A | 25 | mm |
| side B internal width | 116.3 | mm |
| side B internal height | 56.3 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL 3D file 110x110 mm to 80x80 mm – transition: 20 mm (📦 #3644)
1 object(s) - format STL
Rectangular tube adapter downloadable as STL 3D file. Side A uses an internal cross-section of 110x110 mm (square), whereas side B is 80x80 mm (square). Both side A and side B sleeves share the same insertion length of 30 mm. The transition section runs for 20 mm and the overall length is 80 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 110 | mm |
| side A internal height | 110 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 80 | mm |
| side B internal height | 80 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 3 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
3D STL file for rectangular vent adapter. Side A uses an internal cross-section of 100x100 mm (square), whereas side B is 50.5x50.5 mm (square). The sleeve on side A provides an insertion length of 50 mm, and the sleeve on side B 25 mm. The transition section between the two sides is 25 mm long, for an overall length of 100 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 100 | mm |
| side A internal height | 100 | mm |
| sleeve length on side A | 50 | mm |
| side B internal width | 50.5 | mm |
| side B internal height | 50.5 | mm |
| sleeve length on side B | 25 | mm |
| thickness | 3 | mm |
| transition length | 25 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL file 120x120 mm to 80x80 mm – transition: 20 mm (📦 #4172)
1 object(s) - format STL
Rectangular duct adapter exported as STL 3D file. Side A offers an internal cross-section of 120x120 mm (square) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 80 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 120 | mm |
| side A internal height | 120 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 80 | mm |
| side B internal height | 80 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 3 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular adapter exported as STL 3D file. Side A uses an internal cross-section of 111.4x54.4 mm (rectangular), whereas side B is 110.4x54.4 mm (rectangular). Both side A and side B sleeves share the same insertion length of 25 mm. The transition section runs for 20 mm and the overall length is 70 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 111.4 | mm |
| side A internal height | 54.4 | mm |
| sleeve length on side A | 25 | mm |
| side B internal width | 110.4 | mm |
| side B internal height | 54.4 | mm |
| sleeve length on side B | 25 | mm |
| thickness | 2 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL file 71x71 mm to 71x20 mm – transition: 50 mm (📦 #4029)
1 object(s) - format STL
Rectangular duct connector provided as 3D STL file. Side A uses an internal cross-section of 71x71 mm (square), whereas side B is 71x20 mm (rectangular). The sleeve on side A provides an insertion length of 20 mm, and the sleeve on side B 70 mm. The transition section runs for 50 mm and the overall length is 140 mm, sleeves included. The ends are left without chamfers, with sharp inner and outer edges.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 71 | mm |
| side A internal height | 71 | mm |
| sleeve length on side A | 20 | mm |
| side B internal width | 71 | mm |
| side B internal height | 20 | mm |
| sleeve length on side B | 70 | mm |
| thickness | 2 | mm |
| transition length | 50 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | none |
Rectangular duct adapter STL 3D file 155x109.3 mm to 86x40.3 mm – transition: 47.3 mm (📦 #4407)
1 object(s) - format STL
Rectangular vent adapter downloadable as STL 3D file. The internal cross-section on side A is 155x109.3 mm (rectangular), while side B is 86x40.3 mm (rectangular). The insertion length on side A is 10 mm, while on side B it is 52.7 mm. Between the two sleeves, the transition section adds 47.3 mm, giving an overall length of 110 mm. The outer edges at the ends are chamfered, which simplifies inserting the adapter into the mating duct.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 155 | mm |
| side A internal height | 109.3 | mm |
| sleeve length on side A | 10 | mm |
| side B internal width | 86 | mm |
| side B internal height | 40.3 | mm |
| sleeve length on side B | 52.7 | mm |
| thickness | 2 | mm |
| transition length | 47.3 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | outside |
Rectangle-to-rectangle duct adapter STL file 96x51.2 mm to 40x26.2 mm – transition: 55 mm (📦 #4478)
1 object(s) - format STL
3D STL file for rectangular vent adapter. The internal cross-section on side A is 96x51.2 mm (rectangular), while side B is 40x26.2 mm (rectangular). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 55 mm, giving an overall length of 115 mm. The ends are left without chamfers, with sharp inner and outer edges. An offset of 12.5 mm along the Z axis is applied to side B with respect to side A.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 96 | mm |
| side A internal height | 51.2 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 40 | mm |
| side B internal height | 26.2 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 55 | mm |
| Y offset | 0 | mm |
| Z offset | 12.5 | mm |
| end chamfers | none |
Rectangular duct adapter STL file 155x109.3 mm to 91x45.3 mm – transition: 47.3 mm (📦 #4400)
1 object(s) - format STL
Rectangular duct fitting downloadable as STL 3D file. The internal cross-section on side A is 155x109.3 mm (rectangular), while side B is 91x45.3 mm (rectangular). The insertion length on side A is 10 mm, while on side B it is 52.7 mm. The transition section runs for 47.3 mm and the overall length is 110 mm, sleeves included. External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 155 | mm |
| side A internal height | 109.3 | mm |
| sleeve length on side A | 10 | mm |
| side B internal width | 91 | mm |
| side B internal height | 45.3 | mm |
| sleeve length on side B | 52.7 | mm |
| thickness | 2 | mm |
| transition length | 47.3 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | outside |
Rectangular duct adapter STL file 91.2x46.4 mm to 40x21 mm – transition: 55 mm (📦 #4479)
1 object(s) - format STL
Rectangular duct connector downloadable as STL 3D file. Side A offers an internal cross-section of 91.2x46.4 mm (rectangular) and side B uses 40x21 mm (rectangular). Each sleeve provides an insertion length of 30 mm. Between the two sleeves, the transition section adds 55 mm, giving an overall length of 115 mm. Inner and outer edges at both ends are left unchamfered. An offset of 12.7 mm along the Z axis is applied to side B with respect to side A.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 91.2 | mm |
| side A internal height | 46.4 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 40 | mm |
| side B internal height | 21 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 55 | mm |
| Y offset | 0 | mm |
| Z offset | 12.7 | mm |
| end chamfers | none |
Rectangular duct adapter STL 3D file 38x58.6 mm to 80.5x80.5 mm – transition: 30 mm (📦 #5061)
1 object(s) - format STL
Rectangular duct fitting exported as STL 3D file. The internal cross-section on side A is 38x58.6 mm (rectangular), while side B is 80.5x80.5 mm (square). The insertion length on side A is 16 mm, while on side B it is 25 mm. The transition section runs for 30 mm and the overall length is 71 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 38 | mm |
| side A internal height | 58.6 | mm |
| sleeve length on side A | 16 | mm |
| side B internal width | 80.5 | mm |
| side B internal height | 80.5 | mm |
| sleeve length on side B | 25 | mm |
| thickness | 2 | mm |
| transition length | 30 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular duct adapter STL file 100x60 mm to 100x60 mm – transition: 20 mm (📦 #6424)
1 object(s) - format STL
Rectangular pipe adapter provided as 3D STL file. Side A and side B share the same internal cross-section, 100x60 mm, with a rectangular profile. The sleeve on side A provides an insertion length of 30 mm, and the sleeve on side B 70 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 120 mm. The ends are left without chamfers, with sharp inner and outer edges.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 100 | mm |
| side A internal height | 60 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 100 | mm |
| side B internal height | 60 | mm |
| sleeve length on side B | 70 | mm |
| thickness | 2 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | none |
Rectangular tube adapter STL 3D file 150x150 mm to 55x55 mm – transition: 25 mm (📦 #5825)
1 object(s) - format STL
Rectangular duct fitting exported as STL 3D file. The internal cross-section on side A is 150x150 mm (square), while side B is 55x55 mm (square). The insertion length on side A is 50 mm, while on side B it is 25 mm. Between the two sleeves, the transition section adds 25 mm, giving an overall length of 100 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 150 | mm |
| side A internal height | 150 | mm |
| sleeve length on side A | 50 | mm |
| side B internal width | 55 | mm |
| side B internal height | 55 | mm |
| sleeve length on side B | 25 | mm |
| thickness | 3 | mm |
| transition length | 25 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular pipe adapter STL 3D file 96x51.2 mm to 40x23.2 mm – transition: 60 mm (📦 #4438)
1 object(s) - format STL
Rectangular duct connector downloadable as STL 3D file. The internal cross-section on side A is 96x51.2 mm (rectangular), while side B is 40x23.2 mm (rectangular). The sleeve insertion length is the same on both sides, 30 mm. The transition section runs for 60 mm and the overall length is 120 mm, sleeves included. No chamfers are applied at the ends; both inner and outer edges remain sharp. Side B is offset by 24 mm along the Z axis relative to side A.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 96 | mm |
| side A internal height | 51.2 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 40 | mm |
| side B internal height | 23.2 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 60 | mm |
| Y offset | 0 | mm |
| Z offset | 24 | mm |
| end chamfers | none |
Rectangular duct adapter STL 3D file 96x51.2 mm to 40x26.2 mm – transition: 55 mm (📦 #4439)
1 object(s) - format STL
Rectangular duct transition downloadable as STL 3D file. The internal cross-section on side A is 96x51.2 mm (rectangular), while side B is 40x26.2 mm (rectangular). Both side A and side B sleeves share the same insertion length of 30 mm. Between the two sleeves, the transition section adds 55 mm, giving an overall length of 115 mm. Inner and outer edges at both ends are left unchamfered. Relative to side A, side B is shifted by 25 mm along the Z axis.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 96 | mm |
| side A internal height | 51.2 | mm |
| sleeve length on side A | 30 | mm |
| side B internal width | 40 | mm |
| side B internal height | 26.2 | mm |
| sleeve length on side B | 30 | mm |
| thickness | 2 | mm |
| transition length | 55 | mm |
| Y offset | 0 | mm |
| Z offset | 25 | mm |
| end chamfers | none |
Rectangle-to-rectangle duct adapter STL file 104x34 mm to 100x30 mm – transition: 50 mm (📦 #4929)
1 object(s) - format STL
Rectangular pipe adapter downloadable as STL 3D file. The internal cross-section on side A is 104x34 mm (rectangular), while side B is 100x30 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 15 mm. The transition section runs for 50 mm and the overall length is 90 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 104 | mm |
| side A internal height | 34 | mm |
| sleeve length on side A | 25 | mm |
| side B internal width | 100 | mm |
| side B internal height | 30 | mm |
| sleeve length on side B | 15 | mm |
| thickness | 2 | mm |
| transition length | 50 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangular duct adapter STL 3D file 120x120 mm to 94x94 mm – transition: 20 mm (📦 #6955)
1 object(s) - format STL
Rectangular duct adapter downloadable as STL 3D file. The internal cross-section on side A is 120x120 mm (square), while side B is 94x94 mm (square). The insertion length on side A is 40 mm, while on side B it is 24 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 84 mm. Wall thickness is minimal at 1 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 120 | mm |
| side A internal height | 120 | mm |
| sleeve length on side A | 40 | mm |
| side B internal width | 94 | mm |
| side B internal height | 94 | mm |
| sleeve length on side B | 24 | mm |
| thickness | 1 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |
Rectangle-to-rectangle duct adapter STL 3D file 96x51.2 mm to 50x26 mm – transition: 38 mm (📦 #4437)
1 object(s) - format STL
Rectangular conduit adapter provided as 3D STL file. Side A offers an internal cross-section of 96x51.2 mm (rectangular) and side B uses 50x26 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. The transition section runs for 38 mm and the overall length is 78 mm, sleeves included. Wall thickness is minimal at 1 mm. Inner and outer edges at both ends are left unchamfered.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 96 | mm |
| side A internal height | 51.2 | mm |
| sleeve length on side A | 20 | mm |
| side B internal width | 50 | mm |
| side B internal height | 26 | mm |
| sleeve length on side B | 20 | mm |
| thickness | 1 | mm |
| transition length | 38 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | none |
Rectangular tube adapter STL file 79x33 mm to 62x24 mm – transition: 20 mm (📦 #4059)
1 object(s) - format STL
Rectangular duct fitting exported as STL 3D file. Side A offers an internal cross-section of 79x33 mm (rectangular) and side B uses 62x24 mm (rectangular). Both side A and side B sleeves share the same insertion length of 10 mm. The transition section between the two sides is 20 mm long, for an overall length of 40 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
| Parameter | Value | Unit |
|---|---|---|
| side A internal width | 79 | mm |
| side A internal height | 33 | mm |
| sleeve length on side A | 10 | mm |
| side B internal width | 62 | mm |
| side B internal height | 24 | mm |
| sleeve length on side B | 10 | mm |
| thickness | 2 | mm |
| transition length | 20 | mm |
| Y offset | 0 | mm |
| Z offset | 0 | mm |
| end chamfers | inside |