Custom Rectangle-to-rectangle duct adapter STL 3D file 111.4x54.4 mm to 110.4x54.4 mm – transition: 20 mm 📦#9918

STL Download STL 1
Create a new model expert
from scratch search for a model
Rectangular adapter exported as STL 3D file. Side A uses an internal cross-section of 111.4x54.4 mm (rectangular), whereas side B is 110.4x54.4 mm (rectangular). Both side A and side B sleeves share the same insertion length of 25 mm. The transition section runs for 20 mm and the overall length is 70 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Generation date: 2026-07-08
3D Model Rectangle-to-rectangle duct adapter STL 3D file 111.4x54.4 mm to 110.4x54.4 mm – transition: 20 mm

3D model download

Free
  • rectangular-to-rectangular-duc_model9918-nb0_dd{id}.stl : 7.9 Ko
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
Parameter Value
#1 side A internal width 111.4 mm (≃4 3/8 in)
#2 side A internal height 54.4 mm (≃2.14 in)
#3 sleeve length on side A 25 mm (≃0.98 in)
#4 side B internal width 110.4 mm (≃4.35 in)
#5 side B internal height 54.4 mm (≃2.14 in)
#6 sleeve length on side B 25 mm (≃0.98 in)
#7 thickness 2 mm (≃0.08 in)
#8 transition length 20 mm (≃0.79 in)
#9 Y offset 0 mm (0 in)
#10 Z offset 0 mm (0 in)
#11 end chamfers inside
Metadata Value
external width on side A 115.4 mm (≃4.54 in)
external height on side A 58.4 mm (≃2 5/16 in)
external width on side B 114.4 mm (≃4 1/2 in)
external height on side B 58.4 mm (≃2 5/16 in)
total length 70 mm (≃2 3/4 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widRA
#2 side A internal height heiRA
#3 sleeve length on side A lenSA
#4 side B internal width widRB
#5 side B internal height heiRB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter 

3D STL file for rectangular duct connector. Side A uses an internal cross-section of 122.3x60.3 mm (rectangular), whereas side B is 116x56 mm (rectangular). The sleeve on side A provides an insertion length of 25 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 75 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 122.3 mm
side A internal height 60.3 mm
sleeve length on side A 25 mm
side B internal width 116 mm
side B internal height 56 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting provided as 3D STL file. The internal cross-section on side A is 122.3x60.3 mm (rectangular), while side B is 116.3x56.3 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 30 mm. The transition section runs for 20 mm and the overall length is 75 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 122.3 mm
side A internal height 60.3 mm
sleeve length on side A 25 mm
side B internal width 116.3 mm
side B internal height 56.3 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular pipe adapter downloadable as STL 3D file. The internal cross-section on side A is 104x34 mm (rectangular), while side B is 100x30 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 15 mm. The transition section runs for 50 mm and the overall length is 90 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 104 mm
side A internal height 34 mm
sleeve length on side A 25 mm
side B internal width 100 mm
side B internal height 30 mm
sleeve length on side B 15 mm
thickness 2 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct adapter exported as STL 3D file. On both side A and side B, the internal cross-section is 77x34 mm, with a rectangular geometry. Both side A and side B sleeves share the same insertion length of 30 mm. Between the two sleeves, the transition section adds 30 mm, giving an overall length of 90 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 77 mm
side A internal height 34 mm
sleeve length on side A 30 mm
side B internal width 77 mm
side B internal height 34 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting exported as STL 3D file. The internal cross-section on side A is 38x58.6 mm (rectangular), while side B is 80.5x80.5 mm (square). The insertion length on side A is 16 mm, while on side B it is 25 mm. The transition section runs for 30 mm and the overall length is 71 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 38 mm
side A internal height 58.6 mm
sleeve length on side A 16 mm
side B internal width 80.5 mm
side B internal height 80.5 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular adapter downloadable as STL 3D file. The internal cross-section on side A is 77x34 mm (rectangular), while side B is 34x77 mm (rectangular). Each sleeve provides an insertion length of 30 mm. Between the two sleeves, the transition section adds 30 mm, giving an overall length of 90 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 77 mm
side A internal height 34 mm
sleeve length on side A 30 mm
side B internal width 34 mm
side B internal height 77 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting exported as STL 3D file. Side A offers an internal cross-section of 79x33 mm (rectangular) and side B uses 62x24 mm (rectangular). Both side A and side B sleeves share the same insertion length of 10 mm. The transition section between the two sides is 20 mm long, for an overall length of 40 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 79 mm
side A internal height 33 mm
sleeve length on side A 10 mm
side B internal width 62 mm
side B internal height 24 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular tube adapter downloadable as STL 3D file. Side A uses an internal cross-section of 110x110 mm (square), whereas side B is 80x80 mm (square). Both side A and side B sleeves share the same insertion length of 30 mm. The transition section runs for 20 mm and the overall length is 80 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 110 mm
side A internal height 110 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct adapter exported as STL 3D file. Side A offers an internal cross-section of 120x120 mm (square) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 80 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 120 mm
side A internal height 120 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular duct adapter. The internal cross-section on side A is 100x30 mm (rectangular), while side B is 80x20 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. The transition section between the two sides is 20 mm long, for an overall length of 60 mm (side A sleeve, transition and side B sleeve). The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 100 mm
side A internal height 30 mm
sleeve length on side A 20 mm
side B internal width 80 mm
side B internal height 20 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular adapter. Side A offers an internal cross-section of 96x30 mm (rectangular) and side B uses 80x20 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 60 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 96 mm
side A internal height 30 mm
sleeve length on side A 20 mm
side B internal width 80 mm
side B internal height 20 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular adapter provided as 3D STL file. Side A offers an internal cross-section of 200x20 mm (rectangular) and side B uses 100x50 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. The transition section runs for 50 mm and the overall length is 90 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 200 mm
side A internal height 20 mm
sleeve length on side A 20 mm
side B internal width 100 mm
side B internal height 50 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct connector downloadable as STL 3D file. Side A uses an internal cross-section of 100x20 mm (rectangular), whereas side B is 80x20 mm (rectangular). Each sleeve provides an insertion length of 20 mm. The transition section between the two sides is 20 mm long, for an overall length of 60 mm (side A sleeve, transition and side B sleeve). Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 100 mm
side A internal height 20 mm
sleeve length on side A 20 mm
side B internal width 80 mm
side B internal height 20 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct adapter downloadable as STL 3D file. The internal cross-section on side A is 120x120 mm (square), while side B is 94x94 mm (square). The insertion length on side A is 40 mm, while on side B it is 24 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 84 mm. Wall thickness is minimal at 1 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 120 mm
side A internal height 120 mm
sleeve length on side A 40 mm
side B internal width 94 mm
side B internal height 94 mm
sleeve length on side B 24 mm
thickness 1 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular pipe adapter downloadable as STL 3D file. Side A uses an internal cross-section of 42x58.6 mm (rectangular), whereas side B is 80.5x80.5 mm (square). On side A, the sleeve length is 16 mm, and on side B it is 25 mm. The transition section runs for 30 mm and the overall length is 71 mm, sleeves included. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 42 mm
side A internal height 58.6 mm
sleeve length on side A 16 mm
side B internal width 80.5 mm
side B internal height 80.5 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular adapter downloadable as STL 3D file. The internal cross-section on side A is 90x90 mm (square), while side B is 200x20 mm (rectangular). The sleeve on side A provides an insertion length of 15 mm, and the sleeve on side B 10 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 45 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 90 mm
side A internal height 90 mm
sleeve length on side A 15 mm
side B internal width 200 mm
side B internal height 20 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular adapter exported as STL 3D file. The internal cross-section on side A is 38x54.6 mm (rectangular), while side B is 80.5x80.5 mm (square). On side A, the sleeve length is 16 mm, and on side B it is 25 mm. The transition section between the two sides is 30 mm long, for an overall length of 71 mm (side A sleeve, transition and side B sleeve). The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 38 mm
side A internal height 54.6 mm
sleeve length on side A 16 mm
side B internal width 80.5 mm
side B internal height 80.5 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular pipe adapter downloadable as STL 3D file. The internal cross-section on side A is 100x100 mm (square), while side B is 35x35 mm (square). On side A, the sleeve length is 30 mm, and on side B it is 50 mm. The transition section between the two sides is 30 mm long, for an overall length of 110 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 100 mm
side A internal height 100 mm
sleeve length on side A 30 mm
side B internal width 35 mm
side B internal height 35 mm
sleeve length on side B 50 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular vent adapter. Side A uses an internal cross-section of 100x100 mm (square), whereas side B is 50.5x50.5 mm (square). The sleeve on side A provides an insertion length of 50 mm, and the sleeve on side B 25 mm. The transition section between the two sides is 25 mm long, for an overall length of 100 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 100 mm
side A internal height 100 mm
sleeve length on side A 50 mm
side B internal width 50.5 mm
side B internal height 50.5 mm
sleeve length on side B 25 mm
thickness 3 mm
transition length 25 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular conduit adapter downloadable as STL 3D file. Side A offers an internal cross-section of 100x40 mm (rectangular) and side B uses 60x60 mm (square). The sleeve insertion length is the same on both sides, 20 mm. The transition section between the two sides is 50 mm long, for an overall length of 90 mm (side A sleeve, transition and side B sleeve). Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 100 mm
side A internal height 40 mm
sleeve length on side A 20 mm
side B internal width 60 mm
side B internal height 60 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct adapter downloadable as STL 3D file. The internal cross-section on side A is 79x33 mm (rectangular), while side B is 66.7x28 mm (rectangular). Each sleeve provides an insertion length of 10 mm. The transition section runs for 20 mm and the overall length is 40 mm, sleeves included. Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 79 mm
side A internal height 33 mm
sleeve length on side A 10 mm
side B internal width 66.7 mm
side B internal height 28 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none