Custom Hose-shaped reducer STL 3D file 220x100 mm to 185x55 mm – transition: 20 mm 📦#4326

STL Download STL 1
Create a new model expert
from scratch search for a model
Oval duct adapter in STL 3D file format. The internal cross-section on side A is 220x100 mm, while on side B it is 185x55 mm. A uniform useful length of 5 mm is available on both sleeves. The transition links the two ends over 20 mm, with a total overall length of 30 mm. With 1 mm of thickness, the wall remains flexible and material-efficient. The external edges at the ends are chamfered, which simplifies inserting the adapter into the duct. Side B is offset by 9 mm along the Y axis and 9 mm along the Z axis relative to side A.
Generation date: 2025-12-05
3D Model Hose-shaped reducer STL 3D file 220x100 mm to 185x55 mm – transition: 20 mm

3D model download

Free
  • oval-duct-transition-fitting-w_model4326-nb0_dd{id}.stl : 2.2 Mo
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Oval duct transition fitting / hose-shaped reducer template, with the following values:
Parameter Value
#1 side A internal width 220 mm (≃8.66 in)
#2 side A internal height 100 mm (≃3 15/16 in)
#3 sleeve length on side A 5 mm (≃3/16 in)
#4 side B internal width 185 mm (≃7.28 in)
#5 side B internal height 55 mm (≃2.17 in)
#6 sleeve length on side B 5 mm (≃3/16 in)
#7 thickness 1 mm (≃0.04 in)
#8 transition length 20 mm (≃0.79 in)
#9 Y offset 9 mm (≃0.35 in)
#10 Z offset 9 mm (≃0.35 in)
#11 end chamfers outside
Metadata Value
external width on side A 222 mm (≃8 3/4 in)
external height on side A 102 mm (≃4.02 in)
external width on side B 187 mm (≃7 3/8 in)
external height on side B 57 mm (≃2 1/4 in)
total length 30 mm (≃1 3/16 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widOA
#2 side A internal height heiOA
#3 sleeve length on side A lenSA
#4 side B internal width widOB
#5 side B internal height heiOB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Oval duct transition fitting / hose-shaped reducer 

STL 3D file for an oval duct coupling. On side A, the internal cross-section is 220x100 mm, whereas on side B it is 185x55 mm. The sleeve on side A provides a useful length of 5 mm, and on side B 6 mm. The transition links the two ends over 24 mm, with a total overall length of 35 mm. A thickness of 1 mm provides a very light, thin shell. The external chamfers improve fit when inserting the adapter into ducts or hoses. Compared to side A, side B is shifted by 11 mm along the Y axis and 11 mm along the Z axis.
Parameter Value Unit
side A internal width 220 mm
side A internal height 100 mm
sleeve length on side A 5 mm
side B internal width 185 mm
side B internal height 55 mm
sleeve length on side B 6 mm
thickness 1 mm
transition length 24 mm
Y offset 11 mm
Z offset 11 mm
end chamfers outside
STL 3D file for an oval hose fitting. The internal cross-section on side A is 140x80 mm, while on side B it is 130x35 mm. You get a sleeve of 8 mm on side A and 6 mm on side B. The transition links the two ends over 40 mm, with a total overall length of 54 mm. Internal chamfers at the ends improve assembly and make insertion smoother.
Parameter Value Unit
side A internal width 140 mm
side A internal height 80 mm
sleeve length on side A 8 mm
side B internal width 130 mm
side B internal height 35 mm
sleeve length on side B 6 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval connector available as a STL 3D file. On side A, the internal cross-section is 140x50 mm, whereas on side B it is 130x35 mm. You get a sleeve of 8 mm on side A and 6 mm on side B. The central transition occupies 40 mm, bringing the overall length to 54 mm. The internal chamfers help start the duct insertion more easily.
Parameter Value Unit
side A internal width 140 mm
side A internal height 50 mm
sleeve length on side A 8 mm
side B internal width 130 mm
side B internal height 35 mm
sleeve length on side B 6 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval duct transition adapter in STL 3D file format. Side A offers an internal cross-section of 150x40 mm and side B 130x35 mm. The sleeve on side A provides a useful length of 8 mm, and on side B 6 mm. Between the two sleeves, the transition runs over 40 mm, resulting in an overall length of 54 mm. Internal chamfers at the ends improve assembly and make insertion smoother.
Parameter Value Unit
side A internal width 150 mm
side A internal height 40 mm
sleeve length on side A 8 mm
side B internal width 130 mm
side B internal height 35 mm
sleeve length on side B 6 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval hose fitting available as a STL 3D file. On side A, the internal cross-section is 140x40 mm, whereas on side B it is 130x35 mm. On side A, the sleeve is 8 mm long, and on side B 6 mm. The transition portion extends over 20 mm and the overall length, sleeves included, is 34 mm. Internal chamfers at the ends improve assembly and make insertion smoother.
Parameter Value Unit
side A internal width 140 mm
side A internal height 40 mm
sleeve length on side A 8 mm
side B internal width 130 mm
side B internal height 35 mm
sleeve length on side B 6 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval connector available as a STL 3D file. On side A, the internal cross-section is 140x40 mm, whereas on side B it is 130x35 mm. The useful sleeve length on side A is 8 mm, while on side B it reaches 6 mm. The transition section between the two ends is 40 mm long, for an overall length of 54 mm (sleeve A, transition and sleeve B). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 140 mm
side A internal height 40 mm
sleeve length on side A 8 mm
side B internal width 130 mm
side B internal height 35 mm
sleeve length on side B 6 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval duct coupling provided as a STL 3D file. On side A, the internal cross-section is 183x71 mm (oval), whereas on side B it is 98.1x98 mm (nearly circular). The useful sleeve length on side A is 10 mm, while on side B it reaches 50 mm. The transition links the two ends over 30 mm, with a total overall length of 90 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 183 mm
side A internal height 71 mm
sleeve length on side A 10 mm
side B internal width 98.1 mm
side B internal height 98 mm
sleeve length on side B 50 mm
thickness 2 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval connector provided as a STL 3D file. On side A, the internal cross-section is 196x195.9 mm (nearly circular), whereas on side B it is 196x56 mm (oval). The useful lengths are 20 mm (A) and 40 mm (B), respectively. Between the two sleeves, the transition runs over 60 mm, resulting in an overall length of 120 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 196 mm
side A internal height 195.9 mm
sleeve length on side A 20 mm
side B internal width 196 mm
side B internal height 56 mm
sleeve length on side B 40 mm
thickness 2 mm
transition length 60 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
STL 3D file for an oval duct adapter. The internal cross-section on side A is 160x37 mm (oval), while on side B it is 45.1x45 mm (nearly circular). The useful length is consistent on both ends: 20 mm. The transition links the two ends over 20 mm, with a total overall length of 60 mm. External chamfers at the ends help with engagement and assembly within the duct system. Side B is offset by 10 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 160 mm
side A internal height 37 mm
sleeve length on side A 20 mm
side B internal width 45.1 mm
side B internal height 45 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 20 mm
Y offset 10 mm
Z offset 0 mm
end chamfers outside
Oval coupling in STL 3D file format. On side A, the internal cross-section is 121x120.5 mm (nearly circular), whereas on side B it is 90x53 mm (oval). The sleeve on side A provides a useful length of 25 mm, and on side B 30 mm. The transition section is 63 mm long, for a final overall length of 118 mm. Internal chamfers at the ends improve assembly and make insertion smoother. An offset of 31.5 mm along the Z axis is applied to side B relative to side A.
Parameter Value Unit
side A internal width 121 mm
side A internal height 120.5 mm
sleeve length on side A 25 mm
side B internal width 90 mm
side B internal height 53 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 63 mm
Y offset 0 mm
Z offset 31.5 mm
end chamfers inside
STL 3D file for an oval duct fitting. The internal cross-section on side A is 120.1x120 mm (nearly circular), while on side B it is 80x40 mm (oval). On side A, the sleeve is 5 mm long, and on side B 10 mm. The central transition occupies 20 mm, bringing the overall length to 35 mm. A thickness of 4 mm provides good stiffness. The external chamfers improve fit when inserting the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 120.1 mm
side A internal height 120 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
Oval hose adapter in STL 3D file format. The internal cross-section on side A is 158x40 mm (oval), while on side B it is 113x112 mm (nearly circular). Each sleeve provides a useful length of 30 mm. The central transition occupies 20 mm, bringing the overall length to 80 mm. External chamfers are added at the ends to make it easier to insert the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 158 mm
side A internal height 40 mm
sleeve length on side A 30 mm
side B internal width 113 mm
side B internal height 112 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
STL 3D file for an oval duct adapter. On side A, the internal cross-section is 100.1x100 mm (nearly circular), whereas on side B it is 80x40 mm (oval). You get a sleeve of 5 mm on side A and 10 mm on side B. The transition section is 20 mm long, for a final overall length of 35 mm. Wall thickness is generous (4 mm). External chamfers are added at the ends to make it easier to insert the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 100.1 mm
side A internal height 100 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
Oval pipe adapter provided as a STL 3D file. On side A, the internal cross-section is 100x80 mm, whereas on side B it is 80x40 mm. The sleeves also differ in useful length: 5 mm on side A and 10 mm on side B. Between the two sleeves, the transition runs over 20 mm, resulting in an overall length of 35 mm. With 4 mm of wall thickness, the adapter gains extra strength. External chamfers are added at the ends to make it easier to insert the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 100 mm
side A internal height 80 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
STL 3D file for an oval duct coupling. On side A, the internal cross-section is 176x77 mm (oval), whereas on side B it is 77x76 mm (nearly circular). The useful sleeve length is the same on both sides, 20 mm. The transition section between the two ends is 36 mm long, for an overall length of 76 mm (sleeve A, transition and sleeve B). Both the inner and outer edges at the ends remain unchamfered.
Parameter Value Unit
side A internal width 176 mm
side A internal height 77 mm
sleeve length on side A 20 mm
side B internal width 77 mm
side B internal height 76 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 36 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval pipe adapter provided as a STL 3D file. The internal cross-section on side A is 100x70 mm, while on side B it is 80x40 mm. You get a sleeve of 5 mm on side A and 10 mm on side B. The transition section is 20 mm long, for a final overall length of 35 mm. The shell is relatively thick, with a wall thickness of 4 mm. External chamfers are added at the ends to make it easier to insert the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 100 mm
side A internal height 70 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
STL 3D file for an oval connector. On side A, the internal cross-section is 88.9x34.9 mm (oval), whereas on side B it is 46x45 mm (nearly circular). The useful length is consistent on both ends: 10 mm. The transition links the two ends over 20 mm, with a total overall length of 40 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 88.9 mm
side A internal height 34.9 mm
sleeve length on side A 10 mm
side B internal width 46 mm
side B internal height 45 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval connector available as a STL 3D file. The internal cross-section on side A is 91x80 mm, while on side B it is 80x40 mm. The useful sleeve length on side A is 5 mm, while on side B it reaches 10 mm. The transition section between the two ends is 20 mm long, for an overall length of 35 mm (sleeve A, transition and sleeve B). The shell is relatively thick, with a wall thickness of 4 mm. External chamfers are added at the ends to make it easier to insert the adapter into ducts or hoses.
Parameter Value Unit
side A internal width 91 mm
side A internal height 80 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
STL 3D file for an oval hose fitting. On side A, the internal cross-section is 80.1x80 mm (nearly circular), whereas on side B it is 80x40 mm (oval). The sleeve on side A provides a useful length of 5 mm, and on side B 10 mm. The transition section is 20 mm long, for a final overall length of 35 mm. The wall is on the thicker side at 4 mm. External chamfers at the ends help with engagement and assembly within the duct system.
Parameter Value Unit
side A internal width 80.1 mm
side A internal height 80 mm
sleeve length on side A 5 mm
side B internal width 80 mm
side B internal height 40 mm
sleeve length on side B 10 mm
thickness 4 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
Oval pipe adapter available as a STL 3D file. On side A, the internal cross-section is 100x15 mm, whereas on side B it is 50x28 mm. The useful sleeve length is the same on both sides, 10 mm. The transition portion extends over 40 mm and the overall length, sleeves included, is 60 mm. The internal chamfers help start the duct insertion more easily.
Parameter Value Unit
side A internal width 100 mm
side A internal height 15 mm
sleeve length on side A 10 mm
side B internal width 50 mm
side B internal height 28 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
STL 3D file for an oval adapter. The internal cross-section on side A is 120x80 mm, while on side B it is 90x70 mm. The sleeves on sides A and B have the same useful length of 5 mm. The transition section is 30 mm long, for a final overall length of 40 mm. No chamfer is applied at the ends, so both the inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 120 mm
side A internal height 80 mm
sleeve length on side A 5 mm
side B internal width 90 mm
side B internal height 70 mm
sleeve length on side B 5 mm
thickness 3 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
STL 3D file for an oval coupling. Side A offers an internal cross-section of 102x74 mm (oval) and side B 83.5x83 mm (nearly circular). The useful sleeve length on side A is 15 mm, while on side B it reaches 18 mm. The central transition occupies 22 mm, bringing the overall length to 55 mm. No chamfer is applied at the ends, so both the inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 102 mm
side A internal height 74 mm
sleeve length on side A 15 mm
side B internal width 83.5 mm
side B internal height 83 mm
sleeve length on side B 18 mm
thickness 2 mm
transition length 22 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval duct coupling in STL 3D file format. Side A offers an internal cross-section of 102x74 mm (oval) and side B 83.5x83 mm (nearly circular). You get a sleeve of 15 mm on side A and 20 mm on side B. The transition section is 25 mm long, for a final overall length of 60 mm. Both the inner and outer edges at the ends remain unchamfered.
Parameter Value Unit
side A internal width 102 mm
side A internal height 74 mm
sleeve length on side A 15 mm
side B internal width 83.5 mm
side B internal height 83 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 25 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval duct fitting in STL 3D file format. Side A offers an internal cross-section of 120x80 mm and side B 90x70 mm. The useful sleeve length is the same on both sides, 20 mm. The transition portion extends over 30 mm and the overall length, sleeves included, is 70 mm. The ends are left without chamfers, with raw inner and outer edges.
Parameter Value Unit
side A internal width 120 mm
side A internal height 80 mm
sleeve length on side A 20 mm
side B internal width 90 mm
side B internal height 70 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
STL 3D file for an oval connector. Side A offers an internal cross-section of 102x74 mm (oval) and side B 79x78 mm (nearly circular). You get a sleeve of 20 mm on side A and 25 mm on side B. The central transition occupies 32 mm, bringing the overall length to 77 mm. The ends are straight, with no chamfer at all.
Parameter Value Unit
side A internal width 102 mm
side A internal height 74 mm
sleeve length on side A 20 mm
side B internal width 79 mm
side B internal height 78 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 32 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval duct coupling in STL 3D file format. Side A offers an internal cross-section of 102x74 mm (oval) and side B 84x83 mm (nearly circular). The sleeve on side A provides a useful length of 20 mm, and on side B 25 mm. The transition portion extends over 32 mm and the overall length, sleeves included, is 77 mm. The ends are straight, with no chamfer at all.
Parameter Value Unit
side A internal width 102 mm
side A internal height 74 mm
sleeve length on side A 20 mm
side B internal width 84 mm
side B internal height 83 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 32 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval duct transition adapter available as a STL 3D file. On side A, the internal cross-section is 102x74 mm (oval), whereas on side B it is 83.5x83 mm (nearly circular). The useful lengths are 20 mm (A) and 25 mm (B), respectively. The central transition occupies 32 mm, bringing the overall length to 77 mm. Both the inner and outer edges at the ends remain unchamfered.
Parameter Value Unit
side A internal width 102 mm
side A internal height 74 mm
sleeve length on side A 20 mm
side B internal width 83.5 mm
side B internal height 83 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 32 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Oval hose adapter provided as a STL 3D file. On side A, the internal cross-section is 105x35 mm, whereas on side B it is 105x34 mm. The useful sleeve length is the same on both sides, 40 mm. The transition links the two ends over 20 mm, with a total overall length of 100 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 105 mm
side A internal height 35 mm
sleeve length on side A 40 mm
side B internal width 105 mm
side B internal height 34 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Oval coupling available as a STL 3D file. On side A, the internal cross-section is 160x50 mm (oval), whereas on side B it is 45.1x45 mm (nearly circular). Both sleeves share an identical useful length of 20 mm. The transition section between the two ends is 20 mm long, for an overall length of 60 mm (sleeve A, transition and sleeve B). Both the inner and outer edges at the ends remain unchamfered. Side B is offset by 10 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 160 mm
side A internal height 50 mm
sleeve length on side A 20 mm
side B internal width 45.1 mm
side B internal height 45 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 20 mm
Y offset 10 mm
Z offset 0 mm
end chamfers none