Custom Rectangular duct adapter STL file 300x300 mm to 300x300 mm – transition: 20 mm 📦#11001

STL Download STL 1
Create a new model expert
from scratch search for a model
3D STL file for rectangular pipe adapter. Both ends have the same internal cross-section, 300x300 mm, with a square shape. Both side A and side B sleeves share the same insertion length of 65 mm. The transition section between the two sides is 20 mm long, for an overall length of 150 mm (side A sleeve, transition and side B sleeve). The wall is relatively thick, at 5 mm. The ends are left without chamfers, with sharp inner and outer edges.
Generation date: 2026-08-16
3D Model Rectangular duct adapter STL file 300x300 mm to 300x300 mm – transition: 20 mm

3D model download

Free
  • rectangular-to-rectangular-duc_model11001-nb0_dd{id}.stl : 1.6 Ko
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
Parameter Value
#1 side A internal width 300 mm (≃11 13/16 in)
#2 side A internal height 300 mm (≃11 13/16 in)
#3 sleeve length on side A 65 mm (≃2 9/16 in)
#4 side B internal width 300 mm (≃11 13/16 in)
#5 side B internal height 300 mm (≃11 13/16 in)
#6 sleeve length on side B 65 mm (≃2 9/16 in)
#7 thickness 5 mm (≃3/16 in)
#8 transition length 20 mm (≃0.79 in)
#9 Y offset 0 mm (0 in)
#10 Z offset 0 mm (0 in)
#11 end chamfers none
Metadata Value
external width on side A 310 mm (≃12.20 in)
external height on side A 310 mm (≃12.20 in)
external width on side B 310 mm (≃12.20 in)
external height on side B 310 mm (≃12.20 in)
total length 150 mm (≃5.91 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widRA
#2 side A internal height heiRA
#3 sleeve length on side A lenSA
#4 side B internal width widRB
#5 side B internal height heiRB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter 

Rectangular duct adapter provided as 3D STL file. Both ends have the same internal cross-section, 300x300 mm, with a square shape. Each sleeve provides an insertion length of 50 mm. The transition section between the two sides is 50 mm long, for an overall length of 150 mm (side A sleeve, transition and side B sleeve). The wall is particularly robust, with 8 mm of material. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 300 mm
side A internal height 300 mm
sleeve length on side A 50 mm
side B internal width 300 mm
side B internal height 300 mm
sleeve length on side B 50 mm
thickness 8 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct transition downloadable as STL 3D file. The internal cross-section on side A is 295x291 mm (rectangular), while side B is 130x130 mm (square). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 25 mm, giving an overall length of 85 mm. The shell is thick, with a wall thickness of 5 mm. The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 295 mm
side A internal height 291 mm
sleeve length on side A 30 mm
side B internal width 130 mm
side B internal height 130 mm
sleeve length on side B 30 mm
thickness 5 mm
transition length 25 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular vent adapter exported as STL 3D file. Side A and side B share the same internal cross-section, 203x203 mm, with a square profile. The sleeve insertion length is the same on both sides, 30 mm. The transition section between the two sides is 85 mm long, for an overall length of 145 mm (side A sleeve, transition and side B sleeve). No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 203 mm
side A internal height 203 mm
sleeve length on side A 30 mm
side B internal width 203 mm
side B internal height 203 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 85 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular pipe adapter downloadable as STL 3D file. Both ends have the same internal cross-section, 203x203 mm, with a square shape. The sleeve on side A provides an insertion length of 10 mm, and the sleeve on side B 60 mm. Between the two sleeves, the transition section adds 55 mm, giving an overall length of 125 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 203 mm
side A internal height 203 mm
sleeve length on side A 10 mm
side B internal width 203 mm
side B internal height 203 mm
sleeve length on side B 60 mm
thickness 3 mm
transition length 55 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct adapter exported as STL 3D file. Side A and side B share the same internal cross-section, 203.2x203.2 mm, with a square profile. The sleeve on side A provides an insertion length of 20 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 60 mm, giving an overall length of 110 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 203.2 mm
side A internal height 203.2 mm
sleeve length on side A 20 mm
side B internal width 203.2 mm
side B internal height 203.2 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 60 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct sleeve downloadable as STL 3D file. Side A and side B share the same internal cross-section, 203.2x203.2 mm, with a square profile. On side A, the sleeve length is 10 mm, and on side B it is 85 mm. The transition section runs for 58 mm and the overall length is 153 mm, sleeves included. Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 203.2 mm
side A internal height 203.2 mm
sleeve length on side A 10 mm
side B internal width 203.2 mm
side B internal height 203.2 mm
sleeve length on side B 85 mm
thickness 3 mm
transition length 58 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular adapter. Side A and side B share the same internal cross-section, 300x145 mm, with a rectangular profile. The sleeve insertion length is the same on both sides, 85 mm. The transition section between the two sides is 85 mm long, for an overall length of 255 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 300 mm
side A internal height 145 mm
sleeve length on side A 85 mm
side B internal width 300 mm
side B internal height 145 mm
sleeve length on side B 85 mm
thickness 2 mm
transition length 85 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct transition exported as STL 3D file. The internal cross-section on side A is 300x100 mm (rectangular), while side B is 300x180 mm (rectangular). The sleeve on side A provides an insertion length of 100 mm, and the sleeve on side B 20 mm. The transition section between the two sides is 50 mm long, for an overall length of 170 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 300 mm
side A internal height 100 mm
sleeve length on side A 100 mm
side B internal width 300 mm
side B internal height 180 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular conduit adapter. The internal cross-section on side A is 60x284.4 mm (rectangular), while side B is 161.9x191 mm (rectangular). On side A, the sleeve length is 5 mm, and on side B it is 33.5 mm. The transition section runs for 50 mm and the overall length is 88.5 mm, sleeves included. The shell is thick, with a wall thickness of 5 mm. The internal edges at the ends are chamfered to help guide the duct during insertion. Side B is offset by 25 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 60 mm
side A internal height 284.4 mm
sleeve length on side A 5 mm
side B internal width 161.9 mm
side B internal height 191 mm
sleeve length on side B 33.5 mm
thickness 5 mm
transition length 50 mm
Y offset 25 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular duct adapter. The internal cross-section on side A is 171x32 mm (rectangular), while side B is 210.2x209.9 mm (rectangular). The insertion length on side A is 50.8 mm, while on side B it is 31.8 mm. The transition section runs for 55 mm and the overall length is 137.6 mm, sleeves included. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 171 mm
side A internal height 32 mm
sleeve length on side A 50.8 mm
side B internal width 210.2 mm
side B internal height 209.9 mm
sleeve length on side B 31.8 mm
thickness 3 mm
transition length 55 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular adapter exported as STL 3D file. Side A offers an internal cross-section of 171x32 mm (rectangular) and side B uses 209x209 mm (square). On side A, the sleeve length is 50.8 mm, and on side B it is 100 mm. The transition section runs for 55 mm and the overall length is 205.8 mm, sleeves included. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 171 mm
side A internal height 32 mm
sleeve length on side A 50.8 mm
side B internal width 209 mm
side B internal height 209 mm
sleeve length on side B 100 mm
thickness 3 mm
transition length 55 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular vent adapter exported as STL 3D file. The internal cross-section on side A is 60x284.4 mm (rectangular), while side B is 161.9x191 mm (rectangular). The insertion length on side A is 5 mm, while on side B it is 33.5 mm. The transition section between the two sides is 50 mm long, for an overall length of 88.5 mm (side A sleeve, transition and side B sleeve). The shell is thick, with a wall thickness of 4 mm. The internal edges at the ends are chamfered to help guide the duct during insertion. Relative to side A, side B is shifted by 25 mm along the Y axis.
Parameter Value Unit
side A internal width 60 mm
side A internal height 284.4 mm
sleeve length on side A 5 mm
side B internal width 161.9 mm
side B internal height 191 mm
sleeve length on side B 33.5 mm
thickness 4 mm
transition length 50 mm
Y offset 25 mm
Z offset 0 mm
end chamfers inside
Rectangular conduit adapter exported as STL 3D file. On both side A and side B, the internal cross-section is 220x90 mm, with a rectangular geometry. Both side A and side B sleeves share the same insertion length of 50 mm. The transition section between the two sides is 120 mm long, for an overall length of 220 mm (side A sleeve, transition and side B sleeve). No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 50 mm
side B internal width 220 mm
side B internal height 90 mm
sleeve length on side B 50 mm
thickness 3 mm
transition length 120 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular duct sleeve. Side A uses an internal cross-section of 171x32 mm (rectangular), whereas side B is 202x202 mm (square). The insertion length on side A is 50.8 mm, while on side B it is 100 mm. The transition section between the two sides is 55 mm long, for an overall length of 205.8 mm (side A sleeve, transition and side B sleeve). No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 171 mm
side A internal height 32 mm
sleeve length on side A 50.8 mm
side B internal width 202 mm
side B internal height 202 mm
sleeve length on side B 100 mm
thickness 3 mm
transition length 55 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular conduit adapter. Side A and side B share the same internal cross-section, 130x130 mm, with a square profile. Each sleeve provides an insertion length of 90 mm. The transition section between the two sides is 20 mm long, for an overall length of 200 mm (side A sleeve, transition and side B sleeve). Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 130 mm
side A internal height 130 mm
sleeve length on side A 90 mm
side B internal width 130 mm
side B internal height 130 mm
sleeve length on side B 90 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct adapter provided as 3D STL file. Side A offers an internal cross-section of 171x32 mm (rectangular) and side B uses 200x200 mm (square). On side A, the sleeve length is 50.8 mm, and on side B it is 100 mm. The transition section between the two sides is 55 mm long, for an overall length of 205.8 mm (side A sleeve, transition and side B sleeve). No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 171 mm
side A internal height 32 mm
sleeve length on side A 50.8 mm
side B internal width 200 mm
side B internal height 200 mm
sleeve length on side B 100 mm
thickness 3 mm
transition length 55 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular adapter. The internal cross-section on side A is 150x150 mm (square), while side B is 220x150 mm (rectangular). The sleeve on side A provides an insertion length of 9 mm, and the sleeve on side B 60 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 89 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 9 mm
side B internal width 220 mm
side B internal height 150 mm
sleeve length on side B 60 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular pipe adapter downloadable as STL 3D file. Both ends have the same internal cross-section, 150x150 mm, with a square shape. Each sleeve provides an insertion length of 45 mm. The transition section runs for 90 mm and the overall length is 180 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 45 mm
side B internal width 150 mm
side B internal height 150 mm
sleeve length on side B 45 mm
thickness 2 mm
transition length 90 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular adapter. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 180x95 mm (rectangular). Both side A and side B sleeves share the same insertion length of 40 mm. The transition section between the two sides is 30 mm long, for an overall length of 110 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct adapter exported as STL 3D file. Side A uses an internal cross-section of 210.9x210.9 mm (square), whereas side B is 168x31.7 mm (rectangular). On side A, the sleeve length is 40 mm, and on side B it is 32 mm. The transition section runs for 100 mm and the overall length is 172 mm, sleeves included. The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 210.9 mm
side A internal height 210.9 mm
sleeve length on side A 40 mm
side B internal width 168 mm
side B internal height 31.7 mm
sleeve length on side B 32 mm
thickness 3 mm
transition length 100 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct sleeve exported as STL 3D file. Both ends have the same internal cross-section, 150x150 mm, with a square shape. Each sleeve provides an insertion length of 35 mm. The transition section runs for 20 mm and the overall length is 90 mm, sleeves included. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 35 mm
side B internal width 150 mm
side B internal height 150 mm
sleeve length on side B 35 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct transition provided as 3D STL file. Side A uses an internal cross-section of 100x200 mm (rectangular), whereas side B is 60x204 mm (rectangular). Both side A and side B sleeves share the same insertion length of 30 mm. Between the two sleeves, the transition section adds 40 mm, giving an overall length of 100 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp. Relative to side A, side B is shifted by 20 mm along the Y axis and 20 mm along the Z axis.
Parameter Value Unit
side A internal width 100 mm
side A internal height 200 mm
sleeve length on side A 30 mm
side B internal width 60 mm
side B internal height 204 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 40 mm
Y offset 20 mm
Z offset 20 mm
end chamfers none
Rectangular duct adapter downloadable as STL 3D file. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 220x55 mm (rectangular). The sleeve insertion length is the same on both sides, 30 mm. The transition section runs for 20 mm and the overall length is 80 mm, sleeves included. The shell is thick, with a wall thickness of 5 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 30 mm
side B internal width 220 mm
side B internal height 55 mm
sleeve length on side B 30 mm
thickness 5 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular adapter exported as STL 3D file. Both ends have the same internal cross-section, 130x130 mm, with a square shape. Each sleeve provides an insertion length of 82 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 184 mm. The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 130 mm
side A internal height 130 mm
sleeve length on side A 82 mm
side B internal width 130 mm
side B internal height 130 mm
sleeve length on side B 82 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none