Custom Rectangular pipe adapter STL 3D file 150x150 mm to 220x150 mm – transition: 20 mm 📦#7852

STL Download STL 1
Create a new model expert
from scratch search for a model
3D STL file for rectangular adapter. The internal cross-section on side A is 150x150 mm (square), while side B is 220x150 mm (rectangular). The sleeve on side A provides an insertion length of 9 mm, and the sleeve on side B 60 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 89 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Generation date: 2026-03-16
3D Model Rectangular pipe adapter STL 3D file 150x150 mm to 220x150 mm – transition: 20 mm

3D model download

Free
  • rectangular-to-rectangular-duc_model7852-nb0_dd{id}.stl : 52.4 Ko
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
Parameter Value
#1 side A internal width 150 mm (≃5.91 in)
#2 side A internal height 150 mm (≃5.91 in)
#3 sleeve length on side A 9 mm (≃0.35 in)
#4 side B internal width 220 mm (≃8.66 in)
#5 side B internal height 150 mm (≃5.91 in)
#6 sleeve length on side B 60 mm (≃2 3/8 in)
#7 thickness 2 mm (≃0.08 in)
#8 transition length 20 mm (≃0.79 in)
#9 Y offset 0 mm (0 in)
#10 Z offset 0 mm (0 in)
#11 end chamfers inside
Metadata Value
external width on side A 154 mm (≃6 1/16 in)
external height on side A 154 mm (≃6 1/16 in)
external width on side B 224 mm (≃8 13/16 in)
external height on side B 154 mm (≃6 1/16 in)
total length 89 mm (≃3 1/2 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widRA
#2 side A internal height heiRA
#3 sleeve length on side A lenSA
#4 side B internal width widRB
#5 side B internal height heiRB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter 

Rectangular duct sleeve exported as STL 3D file. Both ends have the same internal cross-section, 150x150 mm, with a square shape. Each sleeve provides an insertion length of 35 mm. The transition section runs for 20 mm and the overall length is 90 mm, sleeves included. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 35 mm
side B internal width 150 mm
side B internal height 150 mm
sleeve length on side B 35 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular pipe adapter downloadable as STL 3D file. Both ends have the same internal cross-section, 150x150 mm, with a square shape. Each sleeve provides an insertion length of 45 mm. The transition section runs for 90 mm and the overall length is 180 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 45 mm
side B internal width 150 mm
side B internal height 150 mm
sleeve length on side B 45 mm
thickness 2 mm
transition length 90 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting downloadable as STL 3D file. Side A uses an internal cross-section of 200x150 mm (rectangular), whereas side B is 180x100.4 mm (rectangular). The sleeve on side A provides an insertion length of 5 mm, and the sleeve on side B 20 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 45 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 200 mm
side A internal height 150 mm
sleeve length on side A 5 mm
side B internal width 180 mm
side B internal height 100.4 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular adapter. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 180x95 mm (rectangular). Both side A and side B sleeves share the same insertion length of 40 mm. The transition section between the two sides is 30 mm long, for an overall length of 110 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting exported as STL 3D file. The internal cross-section on side A is 196x146 mm (rectangular), while side B is 180x104 mm (rectangular). The insertion length on side A is 5 mm, while on side B it is 15 mm. The transition section runs for 20 mm and the overall length is 40 mm, sleeves included. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 196 mm
side A internal height 146 mm
sleeve length on side A 5 mm
side B internal width 180 mm
side B internal height 104 mm
sleeve length on side B 15 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular pipe adapter exported as STL 3D file. Side A uses an internal cross-section of 228x98 mm (rectangular), whereas side B is 158x63 mm (rectangular). The sleeve on side A provides an insertion length of 20 mm, and the sleeve on side B 30 mm. The transition section between the two sides is 20 mm long, for an overall length of 70 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 228 mm
side A internal height 98 mm
sleeve length on side A 20 mm
side B internal width 158 mm
side B internal height 63 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct transition exported as STL 3D file. The internal cross-section on side A is 220x90 mm (rectangular), while side B is 205x60 mm (rectangular). Each sleeve provides an insertion length of 40 mm. The transition section between the two sides is 50 mm long, for an overall length of 130 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 205 mm
side B internal height 60 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct connector provided as 3D STL file. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 205x60 mm (rectangular). Both side A and side B sleeves share the same insertion length of 40 mm. Between the two sleeves, the transition section adds 50 mm, giving an overall length of 130 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct. Side B is offset by 15 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 205 mm
side B internal height 60 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 15 mm
end chamfers inside
Rectangular duct adapter exported as STL 3D file. Side A offers an internal cross-section of 120x120 mm (square) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 80 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 120 mm
side A internal height 120 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct sleeve provided as 3D STL file. The internal cross-section on side A is 242x138 mm (rectangular), while side B is 124.6x129 mm (rectangular). Each sleeve provides an insertion length of 5 mm. The transition section runs for 40 mm and the overall length is 50 mm, sleeves included. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 242 mm
side A internal height 138 mm
sleeve length on side A 5 mm
side B internal width 124.6 mm
side B internal height 129 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular adapter exported as STL 3D file. The internal cross-section on side A is 242x138 mm (rectangular), while side B is 123.6x128 mm (rectangular). Both side A and side B sleeves share the same insertion length of 5 mm. The transition section between the two sides is 40 mm long, for an overall length of 50 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 242 mm
side A internal height 138 mm
sleeve length on side A 5 mm
side B internal width 123.6 mm
side B internal height 128 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct sleeve downloadable as STL 3D file. The internal cross-section on side A is 242x138 mm (rectangular), while side B is 123.6x127 mm (rectangular). The sleeve insertion length is the same on both sides, 5 mm. The transition section between the two sides is 40 mm long, for an overall length of 50 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 242 mm
side A internal height 138 mm
sleeve length on side A 5 mm
side B internal width 123.6 mm
side B internal height 127 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular duct adapter. Side A offers an internal cross-section of 242x138 mm (rectangular) and side B uses 123.6x124.6 mm (rectangular). Both side A and side B sleeves share the same insertion length of 5 mm. The transition section between the two sides is 40 mm long, for an overall length of 50 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 242 mm
side A internal height 138 mm
sleeve length on side A 5 mm
side B internal width 123.6 mm
side B internal height 124.6 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 40 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting exported as STL 3D file. The internal cross-section on side A is 246x142 mm (rectangular), while side B is 123.6x124.6 mm (rectangular). Both side A and side B sleeves share the same insertion length of 5 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 30 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 246 mm
side A internal height 142 mm
sleeve length on side A 5 mm
side B internal width 123.6 mm
side B internal height 124.6 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular tube adapter downloadable as STL 3D file. Side A uses an internal cross-section of 110x110 mm (square), whereas side B is 80x80 mm (square). Both side A and side B sleeves share the same insertion length of 30 mm. The transition section runs for 20 mm and the overall length is 80 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 110 mm
side A internal height 110 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct adapter downloadable as STL 3D file. The internal cross-section on side A is 120x120 mm (square), while side B is 94x94 mm (square). The insertion length on side A is 40 mm, while on side B it is 24 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 84 mm. Wall thickness is minimal at 1 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 120 mm
side A internal height 120 mm
sleeve length on side A 40 mm
side B internal width 94 mm
side B internal height 94 mm
sleeve length on side B 24 mm
thickness 1 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct sleeve downloadable as STL 3D file. The internal cross-section on side A is 242x138 mm (rectangular), while side B is 124.6x129 mm (rectangular). Both side A and side B sleeves share the same insertion length of 5 mm. The transition section between the two sides is 60 mm long, for an overall length of 70 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 242 mm
side A internal height 138 mm
sleeve length on side A 5 mm
side B internal width 124.6 mm
side B internal height 129 mm
sleeve length on side B 5 mm
thickness 2 mm
transition length 60 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting downloadable as STL 3D file. The internal cross-section on side A is 155x109.3 mm (rectangular), while side B is 91x45.3 mm (rectangular). The insertion length on side A is 10 mm, while on side B it is 52.7 mm. The transition section runs for 47.3 mm and the overall length is 110 mm, sleeves included. External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes.
Parameter Value Unit
side A internal width 155 mm
side A internal height 109.3 mm
sleeve length on side A 10 mm
side B internal width 91 mm
side B internal height 45.3 mm
sleeve length on side B 52.7 mm
thickness 2 mm
transition length 47.3 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
Rectangular duct sleeve provided as 3D STL file. Side A offers an internal cross-section of 90x220 mm (rectangular) and side B uses 220x90 mm (rectangular). Each sleeve provides an insertion length of 10 mm. The transition section runs for 25 mm and the overall length is 45 mm, sleeves included. External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes.
Parameter Value Unit
side A internal width 90 mm
side A internal height 220 mm
sleeve length on side A 10 mm
side B internal width 220 mm
side B internal height 90 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 25 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
3D STL file for rectangular conduit adapter. Side A uses an internal cross-section of 87x202 mm (rectangular), whereas side B is 90x220 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. The transition section runs for 20 mm and the overall length is 60 mm, sleeves included. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 87 mm
side A internal height 202 mm
sleeve length on side A 20 mm
side B internal width 90 mm
side B internal height 220 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular adapter provided as 3D STL file. On both side A and side B, the internal cross-section is 215x90 mm, with a rectangular geometry. The sleeve insertion length is the same on both sides, 5 mm. The transition section between the two sides is 20 mm long, for an overall length of 30 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 215 mm
side A internal height 90 mm
sleeve length on side A 5 mm
side B internal width 215 mm
side B internal height 90 mm
sleeve length on side B 5 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting provided as 3D STL file. The internal cross-section on side A is 122.3x60.3 mm (rectangular), while side B is 116.3x56.3 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 30 mm. The transition section runs for 20 mm and the overall length is 75 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 122.3 mm
side A internal height 60.3 mm
sleeve length on side A 25 mm
side B internal width 116.3 mm
side B internal height 56.3 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular duct connector. Side A uses an internal cross-section of 122.3x60.3 mm (rectangular), whereas side B is 116x56 mm (rectangular). The sleeve on side A provides an insertion length of 25 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 75 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 122.3 mm
side A internal height 60.3 mm
sleeve length on side A 25 mm
side B internal width 116 mm
side B internal height 56 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular duct sleeve. Side A offers an internal cross-section of 115x115 mm (square) and side B uses 225x90 mm (rectangular). Each sleeve provides an insertion length of 40 mm. Between the two sleeves, the transition section adds 140 mm, giving an overall length of 220 mm. External chamfers at the ends help the adapter slide and seat more easily in the duct system.
Parameter Value Unit
side A internal width 115 mm
side A internal height 115 mm
sleeve length on side A 40 mm
side B internal width 225 mm
side B internal height 90 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 140 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
Rectangular adapter provided as 3D STL file. Side A uses an internal cross-section of 214x84 mm (rectangular), whereas side B is 198x54 mm (rectangular). On side A, the sleeve length is 30 mm, and on side B it is 40 mm. Between the two sleeves, the transition section adds 40 mm, giving an overall length of 110 mm. The outer edges at the ends are chamfered, which simplifies inserting the adapter into the mating duct. An offset of 16 mm along the Z axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 214 mm
side A internal height 84 mm
sleeve length on side A 30 mm
side B internal width 198 mm
side B internal height 54 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 40 mm
Y offset 0 mm
Z offset 16 mm
end chamfers outside
Rectangular pipe adapter provided as 3D STL file. Side A offers an internal cross-section of 214x87 mm (rectangular) and side B uses 215x87 mm (rectangular). Each sleeve provides an insertion length of 5 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 30 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct.
Parameter Value Unit
side A internal width 214 mm
side A internal height 87 mm
sleeve length on side A 5 mm
side B internal width 215 mm
side B internal height 87 mm
sleeve length on side B 5 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular vent adapter exported as STL 3D file. Side A offers an internal cross-section of 214x85 mm (rectangular) and side B uses 215x85 mm (rectangular). The sleeve insertion length is the same on both sides, 5 mm. Between the two sleeves, the transition section adds 20 mm, giving an overall length of 30 mm. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 214 mm
side A internal height 85 mm
sleeve length on side A 5 mm
side B internal width 215 mm
side B internal height 85 mm
sleeve length on side B 5 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside