Custom Rectangular pipe adapter STL 3D file 151x81 mm to 151x81 mm – transition: 150 mm 📦#11869

STL Download STL 1
Create a new model expert
from scratch search for a model
Rectangular duct fitting exported as STL 3D file. On both side A and side B, the internal cross-section is 151x81 mm, with a rectangular geometry. Both side A and side B sleeves share the same insertion length of 40 mm. The transition section runs for 150 mm and the overall length is 230 mm, sleeves included. Internal chamfers are added at the ends to make assembly and duct insertion easier. Relative to side A, side B is shifted by 40 mm along the Y axis and 40 mm along the Z axis.
Generation date: 2026-09-20
3D Model Rectangular pipe adapter STL 3D file 151x81 mm to 151x81 mm – transition: 150 mm

3D model download

Free
  • rectangular-to-rectangular-duc_model11869-nb0_dd{id}.stl : 40.7 Ko
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
Parameter Value
#1 side A internal width 151 mm (≃5 15/16 in)
#2 side A internal height 81 mm (≃3 3/16 in)
#3 sleeve length on side A 40 mm (≃1 9/16 in)
#4 side B internal width 151 mm (≃5 15/16 in)
#5 side B internal height 81 mm (≃3 3/16 in)
#6 sleeve length on side B 40 mm (≃1 9/16 in)
#7 thickness 2 mm (≃0.08 in)
#8 transition length 150 mm (≃5.91 in)
#9 Y offset 40 mm (≃1 9/16 in)
#10 Z offset 40 mm (≃1 9/16 in)
#11 end chamfers inside
Metadata Value
external width on side A 155 mm (≃6.10 in)
external height on side A 85 mm (≃3.35 in)
external width on side B 155 mm (≃6.10 in)
external height on side B 85 mm (≃3.35 in)
total length 230 mm (≃9 1/16 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widRA
#2 side A internal height heiRA
#3 sleeve length on side A lenSA
#4 side B internal width widRB
#5 side B internal height heiRB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter 

Rectangular adapter downloadable as STL 3D file. Side A and side B share the same internal cross-section, 120x40 mm, with a rectangular profile. Each sleeve provides an insertion length of 20 mm. The transition section between the two sides is 80 mm long, for an overall length of 120 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion. An offset of 40 mm along the Y axis and 30 mm along the Z axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 120 mm
side A internal height 40 mm
sleeve length on side A 20 mm
side B internal width 120 mm
side B internal height 40 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 80 mm
Y offset 40 mm
Z offset 30 mm
end chamfers inside
3D STL file for rectangular tube adapter. Side A offers an internal cross-section of 120x60 mm (rectangular) and side B uses 114x54 mm (rectangular). Each sleeve provides an insertion length of 30 mm. Between the two sleeves, the transition section adds 140 mm, giving an overall length of 200 mm. External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes. An offset of 35 mm along the Y axis and 70 mm along the Z axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 120 mm
side A internal height 60 mm
sleeve length on side A 30 mm
side B internal width 114 mm
side B internal height 54 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 140 mm
Y offset 35 mm
Z offset 70 mm
end chamfers outside
Rectangular duct fitting provided as 3D STL file. The internal cross-section on side A is 122x61 mm (rectangular), while side B is 114x54 mm (rectangular). Both side A and side B sleeves share the same insertion length of 30 mm. The transition section runs for 140 mm and the overall length is 200 mm, sleeves included. Inner and outer edges at both ends are left unchamfered. Side B is offset by 70 mm along the Y axis and 35 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 122 mm
side A internal height 61 mm
sleeve length on side A 30 mm
side B internal width 114 mm
side B internal height 54 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 140 mm
Y offset 70 mm
Z offset 35 mm
end chamfers none
Rectangular duct fitting exported as STL 3D file. Side A offers an internal cross-section of 100x40 mm (rectangular) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 30 mm. The transition section runs for 80 mm and the overall length is 140 mm, sleeves included. Inner and outer edges at both ends are left unchamfered. Side B is offset by 30 mm along the Y axis and 30 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 100 mm
side A internal height 40 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 80 mm
Y offset 30 mm
Z offset 30 mm
end chamfers none
Rectangular vent adapter downloadable as STL 3D file. On both side A and side B, the internal cross-section is 204x60 mm, with a rectangular geometry. Both side A and side B sleeves share the same insertion length of 50 mm. The transition section runs for 100 mm and the overall length is 200 mm, sleeves included. Inner and outer edges at both ends are left unchamfered. Side B is offset by 30 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 204 mm
side A internal height 60 mm
sleeve length on side A 50 mm
side B internal width 204 mm
side B internal height 60 mm
sleeve length on side B 50 mm
thickness 2 mm
transition length 100 mm
Y offset 0 mm
Z offset 30 mm
end chamfers none
Rectangular duct adapter downloadable as STL 3D file. Side A offers an internal cross-section of 200x50 mm (rectangular) and side B uses 195x44 mm (rectangular). The insertion length on side A is 20 mm, while on side B it is 30 mm. The transition section between the two sides is 80 mm long, for an overall length of 130 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion. Side B is offset by 15 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 200 mm
side A internal height 50 mm
sleeve length on side A 20 mm
side B internal width 195 mm
side B internal height 44 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 80 mm
Y offset 15 mm
Z offset 0 mm
end chamfers inside
3D STL file for rectangular vent adapter. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 180x95 mm (rectangular). Each sleeve provides an insertion length of 30 mm. The transition section between the two sides is 100 mm long, for an overall length of 160 mm (side A sleeve, transition and side B sleeve). External chamfers at the ends help the adapter slide and seat more easily in the duct system. Relative to side A, side B is shifted by 50 mm along the Y axis.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 30 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 100 mm
Y offset 50 mm
Z offset 0 mm
end chamfers outside
3D STL file for rectangular duct connector. Side A offers an internal cross-section of 220x90 mm (rectangular) and side B uses 180x95 mm (rectangular). Each sleeve provides an insertion length of 30 mm. The transition section between the two sides is 110 mm long, for an overall length of 170 mm (side A sleeve, transition and side B sleeve). The outer edges at the ends are chamfered, which simplifies inserting the adapter into the mating duct. Relative to side A, side B is shifted by 55 mm along the Y axis.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 30 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 110 mm
Y offset 55 mm
Z offset 0 mm
end chamfers outside
Rectangular pipe adapter exported as STL 3D file. Side A offers an internal cross-section of 190x100 mm (rectangular) and side B uses 187.7x97.7 mm (rectangular). The sleeve insertion length is the same on both sides, 30 mm. The transition section runs for 180 mm and the overall length is 240 mm, sleeves included. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 190 mm
side A internal height 100 mm
sleeve length on side A 30 mm
side B internal width 187.7 mm
side B internal height 97.7 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 180 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct adapter downloadable as STL 3D file. The internal cross-section on side A is 200x50 mm (rectangular), while side B is 195x44 mm (rectangular). The sleeve on side A provides an insertion length of 20 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 80 mm, giving an overall length of 130 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier. Side B is offset by 14 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 200 mm
side A internal height 50 mm
sleeve length on side A 20 mm
side B internal width 195 mm
side B internal height 44 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 80 mm
Y offset 0 mm
Z offset 14 mm
end chamfers inside
Rectangular duct transition provided as 3D STL file. Side A offers an internal cross-section of 220x90 mm (rectangular) and side B uses 180x95 mm (rectangular). Both side A and side B sleeves share the same insertion length of 30 mm. Between the two sleeves, the transition section adds 130 mm, giving an overall length of 190 mm. The outer edges at the ends are chamfered, which simplifies inserting the adapter into the mating duct. Relative to side A, side B is shifted by 65 mm along the Y axis.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 30 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 130 mm
Y offset 65 mm
Z offset 0 mm
end chamfers outside
Rectangular duct connector downloadable as STL 3D file. The internal cross-section on side A is 220x90 mm (rectangular), while side B is 180x95 mm (rectangular). Each sleeve provides an insertion length of 40 mm. The transition section runs for 140 mm and the overall length is 220 mm, sleeves included. External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes. An offset of 70 mm along the Y axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 140 mm
Y offset 70 mm
Z offset 0 mm
end chamfers outside
Rectangular adapter exported as STL 3D file. Side A offers an internal cross-section of 220x90 mm (rectangular) and side B uses 220x40 mm (rectangular). On side A, the sleeve length is 30 mm, and on side B it is 50 mm. The transition section between the two sides is 100 mm long, for an overall length of 180 mm (side A sleeve, transition and side B sleeve). External chamfers are added at the ends to make it easier to push the adapter into ducts or pipes. Side B is offset by 50 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 30 mm
side B internal width 220 mm
side B internal height 40 mm
sleeve length on side B 50 mm
thickness 3 mm
transition length 100 mm
Y offset 50 mm
Z offset 0 mm
end chamfers outside
Rectangular duct sleeve exported as STL 3D file. Side A offers an internal cross-section of 190x100 mm (rectangular) and side B uses 186.7x96.7 mm (rectangular). The sleeve insertion length is the same on both sides, 30 mm. Between the two sleeves, the transition section adds 190 mm, giving an overall length of 250 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 190 mm
side A internal height 100 mm
sleeve length on side A 30 mm
side B internal width 186.7 mm
side B internal height 96.7 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 190 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct fitting exported as STL 3D file. Side A offers an internal cross-section of 112x112 mm (square) and side B uses 112x56 mm (rectangular). The insertion length on side A is 25 mm, while on side B it is 30 mm. The transition section between the two sides is 52 mm long, for an overall length of 107 mm (side A sleeve, transition and side B sleeve). The ends are left without chamfers, with sharp inner and outer edges. Side B is offset by 26 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 112 mm
side A internal height 112 mm
sleeve length on side A 25 mm
side B internal width 112 mm
side B internal height 56 mm
sleeve length on side B 30 mm
thickness 2 mm
transition length 52 mm
Y offset 0 mm
Z offset 26 mm
end chamfers none
Rectangular conduit adapter provided as 3D STL file. The internal cross-section on side A is 90x90 mm (square), while side B is 200x20 mm (rectangular). The sleeve on side A provides an insertion length of 15 mm, and the sleeve on side B 10 mm. Between the two sleeves, the transition section adds 70 mm, giving an overall length of 95 mm. The internal edges at the ends are chamfered to help guide the duct during insertion. Relative to side A, side B is shifted by 35 mm along the Z axis.
Parameter Value Unit
side A internal width 90 mm
side A internal height 90 mm
sleeve length on side A 15 mm
side B internal width 200 mm
side B internal height 20 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 70 mm
Y offset 0 mm
Z offset 35 mm
end chamfers inside
Rectangular duct connector provided as 3D STL file. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 205x60 mm (rectangular). Both side A and side B sleeves share the same insertion length of 40 mm. Between the two sleeves, the transition section adds 50 mm, giving an overall length of 130 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct. Side B is offset by 15 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 205 mm
side B internal height 60 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 15 mm
end chamfers inside
Rectangular duct connector exported as STL 3D file. The internal cross-section on side A is 112x112 mm (square), while side B is 112x56 mm (rectangular). Each sleeve provides an insertion length of 25 mm. Between the two sleeves, the transition section adds 52 mm, giving an overall length of 102 mm. The ends are left without chamfers, with sharp inner and outer edges. Side B is offset by 26 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 112 mm
side A internal height 112 mm
sleeve length on side A 25 mm
side B internal width 112 mm
side B internal height 56 mm
sleeve length on side B 25 mm
thickness 2 mm
transition length 52 mm
Y offset 0 mm
Z offset 26 mm
end chamfers none
Rectangular pipe adapter downloadable as STL 3D file. Both ends have the same internal cross-section, 150x150 mm, with a square shape. Each sleeve provides an insertion length of 45 mm. The transition section runs for 90 mm and the overall length is 180 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 150 mm
side A internal height 150 mm
sleeve length on side A 45 mm
side B internal width 150 mm
side B internal height 150 mm
sleeve length on side B 45 mm
thickness 2 mm
transition length 90 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct connector exported as STL 3D file. The internal cross-section on side A is 90x90 mm (square), while side B is 200x20 mm (rectangular). The sleeve on side A provides an insertion length of 15 mm, and the sleeve on side B 10 mm. The transition section between the two sides is 60 mm long, for an overall length of 85 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier. An offset of 30 mm along the Z axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 90 mm
side A internal height 90 mm
sleeve length on side A 15 mm
side B internal width 200 mm
side B internal height 20 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 60 mm
Y offset 0 mm
Z offset 30 mm
end chamfers inside
Rectangular duct adapter provided as 3D STL file. The internal cross-section on side A is 200x20 mm (rectangular), while side B is 100x50 mm (rectangular). Each sleeve provides an insertion length of 20 mm. Between the two sleeves, the transition section adds 50 mm, giving an overall length of 90 mm. Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct. An offset of 25 mm along the Z axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 200 mm
side A internal height 20 mm
sleeve length on side A 20 mm
side B internal width 100 mm
side B internal height 50 mm
sleeve length on side B 20 mm
thickness 3 mm
transition length 50 mm
Y offset 0 mm
Z offset 25 mm
end chamfers inside
Rectangular adapter exported as STL 3D file. Side A uses an internal cross-section of 90x90 mm (square), whereas side B is 200x20 mm (rectangular). The insertion length on side A is 15 mm, while on side B it is 10 mm. The transition section between the two sides is 50 mm long, for an overall length of 75 mm (side A sleeve, transition and side B sleeve). Internal chamfers at the ends improve assembly and provide a smoother insertion of the mating duct. Relative to side A, side B is shifted by 25 mm along the Z axis.
Parameter Value Unit
side A internal width 90 mm
side A internal height 90 mm
sleeve length on side A 15 mm
side B internal width 200 mm
side B internal height 20 mm
sleeve length on side B 10 mm
thickness 2 mm
transition length 50 mm
Y offset 0 mm
Z offset 25 mm
end chamfers inside
Rectangular duct connector downloadable as STL 3D file. The internal cross-section on side A is 225x90 mm (rectangular), while side B is 150x75 mm (rectangular). On side A, the sleeve length is 35 mm, and on side B it is 20 mm. Between the two sleeves, the transition section adds 100 mm, giving an overall length of 155 mm. External chamfers at the ends help the adapter slide and seat more easily in the duct system.
Parameter Value Unit
side A internal width 225 mm
side A internal height 90 mm
sleeve length on side A 35 mm
side B internal width 150 mm
side B internal height 75 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 100 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside
3D STL file for rectangular duct sleeve. Side A offers an internal cross-section of 115x115 mm (square) and side B uses 225x90 mm (rectangular). Each sleeve provides an insertion length of 40 mm. Between the two sleeves, the transition section adds 140 mm, giving an overall length of 220 mm. External chamfers at the ends help the adapter slide and seat more easily in the duct system.
Parameter Value Unit
side A internal width 115 mm
side A internal height 115 mm
sleeve length on side A 40 mm
side B internal width 225 mm
side B internal height 90 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 140 mm
Y offset 0 mm
Z offset 0 mm
end chamfers outside