?>

Custom Rectangular duct adapter STL file 120x40 mm to 120x40 mm – transition: 80 mm 📦#3965

STL Download STL
Create a new model:
from scratch search for a model
Rectangular adapter downloadable as STL 3D file. Side A and side B share the same internal cross-section, 120x40 mm, with a rectangular profile. Each sleeve provides an insertion length of 20 mm. The transition section between the two sides is 80 mm long, for an overall length of 120 mm (side A sleeve, transition and side B sleeve). The internal edges at the ends are chamfered to help guide the duct during insertion. An offset of 40 mm along the Y axis and 30 mm along the Z axis is applied to side B with respect to side A.
Generation date: 2025-11-28
3D Model Rectangular duct adapter STL file 120x40 mm to 120x40 mm – transition: 80 mm

3D model download

Free
  • rectangular-to-rectangular-duc_model3965-nb0_dd{id}.stl : 50.9 Ko
STL Mesh quality : Linear deflection 0.0005 Angular deflection 0.05
No compliance warranty No compliance warranty
(Internal and private use, non-commercial – no distribution – no derivatives)
Safe download
Instant .zip download — no email, no account

Values for this model

This model was generated by the Rectangular-to-rectangular duct adapter template, with the following values:
Parameter Value
#1 side A internal width 120 mm (≃4.72 in)
#2 side A internal height 40 mm (≃1 9/16 in)
#3 sleeve length on side A 20 mm (≃0.79 in)
#4 side B internal width 120 mm (≃4.72 in)
#5 side B internal height 40 mm (≃1 9/16 in)
#6 sleeve length on side B 20 mm (≃0.79 in)
#7 thickness 3 mm (≃1/8 in)
#8 transition length 80 mm (≃3.15 in)
#9 Y offset 40 mm (≃1 9/16 in)
#10 Z offset 30 mm (≃1 3/16 in)
#11 end chamfers inside
Metadata Value
external width on side A 126 mm (≃4.96 in)
external height on side A 46 mm (≃1 13/16 in)
external width on side B 126 mm (≃4.96 in)
external height on side B 46 mm (≃1 13/16 in)
total length 120 mm (≃4.72 in)
illustration of the parameters
Parameter overview

Labels are used in the naming of the downloaded 3D files.

Parameter Label
#1 side A internal width widRA
#2 side A internal height heiRA
#3 sleeve length on side A lenSA
#4 side B internal width widRB
#5 side B internal height heiRB
#6 sleeve length on side B lenSB
#7 thickness thi
#8 transition length tra
#9 Y offset ofsY
#10 Z offset ofsZ
#11 end chamfers cha

Related 3D models

To search for a model based on your own parameters, go to the template page Rectangular-to-rectangular duct adapter 

Rectangular duct fitting exported as STL 3D file. Side A offers an internal cross-section of 100x40 mm (rectangular) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 30 mm. The transition section runs for 80 mm and the overall length is 140 mm, sleeves included. Inner and outer edges at both ends are left unchamfered. Side B is offset by 30 mm along the Y axis and 30 mm along the Z axis relative to side A.
Parameter Value Unit
side A internal width 100 mm
side A internal height 40 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 80 mm
Y offset 30 mm
Z offset 30 mm
end chamfers none
Rectangular duct transition downloadable as STL 3D file. Both ends have the same internal cross-section, 60x60 mm, with a square shape. The sleeve insertion length is the same on both sides, 20 mm. The transition section runs for 60 mm and the overall length is 100 mm, sleeves included. The shell is thick, with a wall thickness of 4 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp. An offset of 30 mm along the Y axis is applied to side B with respect to side A.
Parameter Value Unit
side A internal width 60 mm
side A internal height 60 mm
sleeve length on side A 20 mm
side B internal width 60 mm
side B internal height 60 mm
sleeve length on side B 20 mm
thickness 4 mm
transition length 60 mm
Y offset 30 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular duct adapter. The internal cross-section on side A is 100x30 mm (rectangular), while side B is 80x20 mm (rectangular). The sleeve insertion length is the same on both sides, 20 mm. The transition section between the two sides is 20 mm long, for an overall length of 60 mm (side A sleeve, transition and side B sleeve). The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 100 mm
side A internal height 30 mm
sleeve length on side A 20 mm
side B internal width 80 mm
side B internal height 20 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct connector downloadable as STL 3D file. Side A uses an internal cross-section of 100x20 mm (rectangular), whereas side B is 80x20 mm (rectangular). Each sleeve provides an insertion length of 20 mm. The transition section between the two sides is 20 mm long, for an overall length of 60 mm (side A sleeve, transition and side B sleeve). Inner and outer edges at both ends are left unchamfered.
Parameter Value Unit
side A internal width 100 mm
side A internal height 20 mm
sleeve length on side A 20 mm
side B internal width 80 mm
side B internal height 20 mm
sleeve length on side B 20 mm
thickness 2 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular tube adapter downloadable as STL 3D file. Side A uses an internal cross-section of 110x110 mm (square), whereas side B is 80x80 mm (square). Both side A and side B sleeves share the same insertion length of 30 mm. The transition section runs for 20 mm and the overall length is 80 mm, sleeves included. The internal edges at the ends are chamfered to help guide the duct during insertion.
Parameter Value Unit
side A internal width 110 mm
side A internal height 110 mm
sleeve length on side A 30 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 3 mm
transition length 20 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular duct connector downloadable as STL 3D file. Side A offers an internal cross-section of 60x60 mm (square) and side B uses 80x80 mm (square). The sleeve insertion length is the same on both sides, 10 mm. The transition section runs for 180 mm and the overall length is 200 mm, sleeves included. The wall is thin, with a thickness of 1 mm. Internal chamfers are added at the ends to make assembly and duct insertion easier. Side B is offset by 90 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 60 mm
side A internal height 60 mm
sleeve length on side A 10 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 10 mm
thickness 1 mm
transition length 180 mm
Y offset 90 mm
Z offset 0 mm
end chamfers inside
Rectangular conduit adapter exported as STL 3D file. The internal cross-section on side A is 60x60 mm (square), while side B is 80x80 mm (square). The sleeve insertion length is the same on both sides, 10 mm. The transition section between the two sides is 180 mm long, for an overall length of 200 mm (side A sleeve, transition and side B sleeve). The wall is thin, with a thickness of 1 mm. No chamfers are applied at the ends; both inner and outer edges remain sharp.
Parameter Value Unit
side A internal width 60 mm
side A internal height 60 mm
sleeve length on side A 10 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 10 mm
thickness 1 mm
transition length 180 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular duct sleeve downloadable as STL 3D file. The internal cross-section on side A is 200x90 mm (rectangular), while side B is 80x80 mm (square). The insertion length on side A is 40 mm, while on side B it is 30 mm. Between the two sleeves, the transition section adds 60 mm, giving an overall length of 130 mm. Wall thickness is generous (4 mm). The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 200 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 4 mm
transition length 60 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
Rectangular vent adapter provided as 3D STL file. Side A offers an internal cross-section of 20x90 mm (rectangular) and side B uses 80x80 mm (square). The sleeve on side A provides an insertion length of 40 mm, and the sleeve on side B 30 mm. Between the two sleeves, the transition section adds 60 mm, giving an overall length of 130 mm. The shell is thick, with a wall thickness of 4 mm. The ends are left without chamfers, with sharp inner and outer edges.
Parameter Value Unit
side A internal width 20 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 80 mm
side B internal height 80 mm
sleeve length on side B 30 mm
thickness 4 mm
transition length 60 mm
Y offset 0 mm
Z offset 0 mm
end chamfers none
3D STL file for rectangular adapter. Side A uses an internal cross-section of 220x90 mm (rectangular), whereas side B is 180x95 mm (rectangular). Both side A and side B sleeves share the same insertion length of 40 mm. The transition section between the two sides is 30 mm long, for an overall length of 110 mm (side A sleeve, transition and side B sleeve). Internal chamfers are added at the ends to make assembly and duct insertion easier.
Parameter Value Unit
side A internal width 220 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 180 mm
side B internal height 95 mm
sleeve length on side B 40 mm
thickness 3 mm
transition length 30 mm
Y offset 0 mm
Z offset 0 mm
end chamfers inside
Rectangular tube adapter exported as STL 3D file. Side A uses an internal cross-section of 90x90 mm (square), whereas side B is 200x90 mm (rectangular). The sleeve insertion length is the same on both sides, 40 mm. The transition section between the two sides is 100 mm long, for an overall length of 180 mm (side A sleeve, transition and side B sleeve). The shell is very thick, with 6 mm wall thickness. The internal edges at the ends are chamfered to help guide the duct during insertion. Side B is offset by 50 mm along the Y axis relative to side A.
Parameter Value Unit
side A internal width 90 mm
side A internal height 90 mm
sleeve length on side A 40 mm
side B internal width 200 mm
side B internal height 90 mm
sleeve length on side B 40 mm
thickness 6 mm
transition length 100 mm
Y offset 50 mm
Z offset 0 mm
end chamfers inside